Drive Parameter Setting of Mitsubishi drive with motor full explained
The Basic Parameter Set-up of Mitsubishi Drive with motor.

ENGINEERING TECH
4 min readJul 12, 2021

The Basic Parameter Set-up of Mitsubishi Drive with motor.

Parameter Set-up of Mitsubishi Drive [ FR-D700- Parameter Settings ]

Search

Search

Drive Parameter Settings [ FR-D700 ]

P.. 0 [ FR-D700 ]

Parameter 0

What is Set-Up of Parameter :- 0 [ Torque Boost ]

Increments :- 0.1 %

Initial Value :- 6/4/3%

Range :- 0–30%

Note :- Set to the increase Starting torque or when the motor with a load will not rotate, Resulting in an alarm (OL) and a Trip ( OC1).

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

P.. 1 [ FR-D700 ]

Parameter 1

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up

What is Set-Up of Parameter :- 1

[ Maximum Frequency ]

Increments :- 0.01 Hz

Initial Value :- 120 Hz

Range :- 0–120 Hz

Note :- Set when the Maximum O/P frequency need to be Limited.

P.. 2 [ FR-D700 ]

Parameter 2

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Drive Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

What is Set-Up of Parameter :- 2 [ Minimum Frequency ]

Increments :- 0.01 Hz

Initial Value :- 0 Hz

Range :- 0–120 Hz

Note :- Set when the Minimum O/P frequency need to be Limited

P.. 3 [ FR-D700 ]

Parameter 3

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Drive Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

What is Set-Up of Parameter :- 3 [ Base Frequency ]

Increments :- 0.01 Hz

Initial Value :- 50 Hz

Range :- 0–400 Hz

Note :- Check the Motor Rating Plate.

P.. 4 , 5, 6 [ FR-D700 ]

Parameter 4–5–6

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

Parameter 4–5–6 [ Multi Speed Setting ]

Parameter 4 :- RH ( High ) — 50 Hz

Parameter 5 :- RM ( Medium ) — 30 Hz

Parameter 6 :- RL ( Low ) — 10 Hz

Increments :- 0.01 Hz

Range :- 0–400 Hz

Note :- Set When changing the preset Speed in the Parameter with a terminal.

P.. 7, 8 [ FR-D700 ]

Parameter 7, 8

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

Parameter :- 7 [ Acceleration Time ]

Parameter :- 8 [ Deceleration Time ]

Increments :- 0.1 Second

Initial Value :- 5 / 10s

Range :- 0–3600 second

Note :- Acceleration Time / Deceleration Time Can be set.

P.. 9 [ FR-D700 ]

Parameter 9

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

Parameter :- 9 [ Electronic Thermal Overload Relay ]

Increments :- 0.01 A

Initial Value :- Rated inverter Current

Range :- 0–500 A

Note :- Protect the Motor Overheat by the inverter. Set the motor rated Current.

P.. 79 [ FR-D700 ]

Parameter 79

Here is already Parameter :-1 Set-up of Mitsubishi Drive With motor.

Step by Step Follow and Set-up.

We Can show in this Picture And Set-up Other Parameter set-up Same this Type Format. Only For change a Parameter Sequence Like That

Parameter 1.. 2…3 … +++++

Parameter :- 79 [ Operation Mode Selection ]

Increments :- 1

Initial Value :- 0

Range :- 0–1–2–3–4–5–6–7

Note :- Select the Start Command location and Frequency Command Location.

More Knowledge of Mitsubishi Drive Parameter Settings So Next Topic is It’s Connection with Video.

--

--

ENGINEERING TECH

Electrical maintenance engineer at ( Voltasbeko + koc + TATA GROUP + Archelik ) in sanand Gujarat Electrical Engineer work at Maruti Suzuki real experience.